Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 488
Filtrar
1.
Int J Ophthalmol ; 17(3): 485-490, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38721517

RESUMO

AIM: To investigate the long-term changes of corneal densitometry (CD) and its contributing elements after small incision lenticule extraction (SMILE). METHODS: Totally 31 eyes of 31 patients with mean spherical equivalent of -6.46±1.50 D and mean age 28.23±7.38y were enrolled. Full-scale examinations were conducted on all patients preoperatively and during follow-up. Visual acuity, manifest refraction, axial length, corneal thickness, corneal higher-order aberrations, and CD were evaluated. RESULTS: All surgeries were completed successfully without complications or adverse events. Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28. CD value of 0-6 mm zones in central layer was statistically significantly lower 10y postoperatively, compared with preoperative values (0-2 mmΔ=-1.62, 2-6 mmΔ=-1.24, P<0.01). There were no correlations between CD values and factors evaluated. CONCLUSION: SMILE is a safe and efficient procedure for myopia on a long-term basis. CD values get lower 10y postoperatively, whose mechanism is to be further discussed.

2.
Am J Ophthalmol ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38701876

RESUMO

PURPOSE: To evaluate the visual outcomes and perioperative complications for cataract surgery in eyes with axial length (AL) > 33.0 mm. DESIGN: Prospective clinical cohort study. METHODS: One hundred and twenty-two eyes with moderate high myopia (26.0 mm ≤ AL<28.0 mm, control group), and 118 eyes with extreme high myopia (AL > 33.0 mm, EHM group) were followed up after cataract surgery (one week and one year post-op). Myopic maculopathy grading according to ATN system, best-corrected visual acuity (BCVA), and complications were compared. RESULTS: Postoperatively, BCVA in the EHM group improved significantly at both visits (both P < 0.001), despite being worse than that of the control group (both P < 0.05). The EHM group exhibited greater hyperopic refractive errors (P < 0.001), which were found to be associated with more severe T grade, longer AL, poorer second follow-up BCVA, and smaller anterior capsular opening (ACO) area. A higher incidence of retinal detachment and a more constricted ACO were observed in the EHM group (P = 0.030 and < 0.001, respectively), with the latter being significantly associated with longer AL and the absence of capsular tension ring (both P < 0.05). No difference in BCVA was found between the aphakic and pseudophakic eyes in the EHM group at both visits (both P > 0.05). CONCLUSION: Cataract surgery improves vision of eyes with AL > 33 mm, yet the increased risk of perioperative complications requires attention. Leaving these eyes aphakic might be effective and safe in the long term.

3.
Precis Clin Med ; 7(1): pbae005, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38558949

RESUMO

Background: Myopia is a leading cause of visual impairment in Asia and worldwide. However, accurately predicting the progression of myopia and the high risk of myopia remains a challenge. This study aims to develop a predictive model for the development of myopia. Methods: We first retrospectively gathered 612 530 medical records from five independent cohorts, encompassing 227 543 patients ranging from infants to young adults. Subsequently, we developed a multivariate linear regression algorithm model to predict the progression of myopia and the risk of high myopia. Result: The model to predict the progression of myopia achieved an R2 value of 0.964 vs a mean absolute error (MAE) of 0.119D [95% confidence interval (CI): 0.119, 1.146] in the internal validation set. It demonstrated strong generalizability, maintaining consistent performance across external validation sets: R2 = 0.950 vs MAE = 0.119D (95% CI: 0.119, 1.136) in validation study 1, R2 = 0.950 vs MAE = 0.121D (95% CI: 0.121, 1.144) in validation study 2, and R2 = 0.806 vs MAE = -0.066D (95% CI: -0.066, 0.569) in the Shanghai Children Myopia Study. In the Beijing Children Eye Study, the model achieved an R2 of 0.749 vs a MAE of 0.178D (95% CI: 0.178, 1.557). The model to predict the risk of high myopia achieved an area under the curve (AUC) of 0.99 in the internal validation set and consistently high area under the curve values of 0.99, 0.99, 0.96 and 0.99 in the respective external validation sets. Conclusion: Our study demonstrates accurate prediction of myopia progression and risk of high myopia providing valuable insights for tailoring strategies to personalize and optimize the clinical management of myopia in children.

4.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593257

RESUMO

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Assuntos
Astigmatismo , Humanos , Adulto Jovem , Adulto , Estudos Prospectivos , Córnea , Pupila , Biometria , Topografia da Córnea , Refração Ocular
5.
Am J Ophthalmol ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38621521

RESUMO

PURPOSE: To compare agreement of corneal epithelium thickness (ET) between AS-OCT system (RTVue, Optovue, Fremont, USA) and AS-OCT/Placido topographer (MS-39, CSO, Florence, Italy) in different stages keratoconus (KC) eyes, and to assess the repeatability of RTVue AS-OCT. DESIGN: Prospective reliability analysis. METHODS: KC eyes were classified into forme fruste KC (FFKC), mild, moderate and severe KC. Agreement was evaluated with Bland-Altman plots and 95% limits of agreement (LoA). The repeatability of RTVue was assessed via within-subject standard deviation (Sw), test-retest variability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). RESULTS: Totally, 119 KC eyes were enrolled, with 21 FFKC, 26 mild, 39 moderate, and 34 severe. The 95% LoA ranged between -5.9 and 4.8 µm for center epithelium thickness (CET), between -5.7 and 8.2 µm for thinnest epithelium thickness (TET). At 1mm measuring points, the 95% LoA of superior, inferior, nasal and temporal were -4.2 to 4.7 µm, -5.2 to 6.0 µm, -7.9 to 10.2 µm, -11.2 to 6.0 µm. At 3mm measuring points, the corresponding values were -2.8 to 9.3 µm, -2.0 to 13.0 µm, -4.6 to 9.6 µm, -6.3 to 9.7 µm, indicating the two instruments weren't interchangeable without adjustment. Despite the repeatability of RTVue in KC patients were acceptable, repeatability decreased gradually with the peripheralization of the measurement points. CONCLUSIONS: The two OCT-based devices, RTVue and MS-39, don't provide interchangeable measurements of ET in KC patients. Repeatability decreases in severer KC, emphasizing the importance of grading before clinical examination to avoid diagnostic errors.

6.
Adv Sci (Weinh) ; : e2401710, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582513

RESUMO

Corneal neovascularization (CNV) is a common clinical finding seen in a range of eye diseases. Current therapeutic approaches to treat corneal angiogenesis, in which vascular endothelial growth factor (VEGF) A plays a central role, can cause a variety of adverse side effects. The technology of Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/Cas9 can edit VEGFA gene to suppress its expression. CRISPR offers a novel opportunity to treat CNV. This study shows that depletion of VEGFA with a novel CRISPR/Cas9 system inhibits proliferation, migration, and tube formation of human umbilical vein endothelial cells (HUVECs) in vitro. Importantly, subconjunctival injection of this dual AAV-SpCas9/sgRNA-VEGFA system is demonstrated which blocks suture-induced expression of VEGFA, CD31, and α-smooth muscle actin as well as corneal neovascularization in mice. This study has established a strong foundation for the treatment of corneal neovascularization via a gene editing approach for the first time.

7.
J Transl Med ; 22(1): 405, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689321

RESUMO

BACKGROUND: Retinal detachment (RD) is a vision-threatening disorder of significant severity. Individuals with high myopia (HM) face a 2 to 6 times higher risk of developing RD compared to non-myopes. The timely identification of high myopia-related retinal detachment (HMRD) is crucial for effective treatment and prevention of additional vision impairment. Consequently, our objective was to streamline and validate a machine-learning model based on clinical laboratory omics (clinlabomics) for the early detection of RD in HM patients. METHODS: We extracted clinlabomics data from the electronic health records for 24,440 HM and 5607 HMRD between 2015 and 2022. Lasso regression analysis assessed fifty-nine variables, excluding collinear variables (variance inflation factor > 10). Four models based on random forest, gradient boosting machine (GBM), generalized linear model, and Deep Learning Model were trained for HMRD diagnosis and employed for internal validation. An external test of the models was done. Three random data sets were further processed to validate the performance of the diagnostic model. The primary outcomes were the area under the receiver operating characteristic curve (AUC) and the area under the precision-recall curve (AUCPR) to diagnose HMRD. RESULTS: Nine variables were selected by all models. Given the AUC and AUCPR values across the different sets, the GBM model was chosen as the final diagnostic model. The GBM model had an AUC of 0.8550 (95%CI = 0.8322-0.8967) and an AUCPR of 0.5584 (95%CI = 0.5250-0.5879) in the training set. The AUC and AUCPR in the internal validation were 0.8405 (95%CI = 0.8060-0.8966) and 0.5355 (95%CI = 0.4988-0.5732). During the external test evaluation, it reached an AUC of 0.7579 (95%CI = 0.7340-0.7840) and an AUCPR of 0.5587 (95%CI = 0.5345-0.5880). A similar discriminative capacity was observed in the three random data sets. The GBM model was well-calibrated across all the sets. The GBM-RD model was implemented into a web application that provides risk prediction for HM individuals. CONCLUSION: GBM algorithms based on nine features successfully predicted the diagnosis of RD in patients with HM, which will help ophthalmologists to establish a preliminary diagnosis and to improve diagnostic accuracy in the clinic.


Assuntos
Diagnóstico Precoce , Aprendizado de Máquina , Miopia , Curva ROC , Descolamento Retiniano , Humanos , Miopia/diagnóstico , Miopia/complicações , Descolamento Retiniano/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto , Área Sob a Curva
8.
Heliyon ; 10(6): e28036, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38524541

RESUMO

Here, we have reported the genetic and clinical characteristics of four generations of a family patient from China with congenital fibrosis of extraocular muscles 1 (CFEOM1) and keratoconus (KC). The history of diseases, clinical observations, and blood samples of all family members were collected. A total of 100 healthy participants were recruited as normal controls. The whole exome sequencing of the genomic DNA and polymerase chain reaction were performed on samples obtained from the controls and their family members to verify the gene variants. The functional analyses of the variants were performed by using different software. Two single nucleotide polymorphisms were detected in the proband and other patients in his families, including a heterozygous missense variation, g.39726207C > T (c.2860C > T, p.R954W, rs121912585), in the third highly conserved coiled-coil domain of KIF21A, and a heterozygous missense variant, g.30664732A > C (c.136A > C, p.S46R, rs200111443) in TGFBR2. The variant p.R954W in KIF21A was predicted to be pathogenic using software, whereas p.S46R in TGFBR2 was predicted to be of uncertain significance (VUS). Thus, KC might have occurred in the proband and his daughter because of a combination of genetic mutations and involuntary eye rubbing induced by CFEOM1. This is the first case of concomitant KC in a family having CFEOM1. Thus, the study provides new information about patients with KC having CFEOM1. Furthermore, the study suggests that attention should be paid to the early detection and diagnosis of KC in patients with CFEOM1.

9.
Biomedicines ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38540168

RESUMO

Implantable Collamer Lens (ICL) surgery has increasingly been adopted for myopia correction in recent decades. This study, employing in vivo confocal microscopy (IVCM), aimed to assess the impact of corneal incision during ICL surgery on the corneal sub-basal nerve plexus (SNP) and adjacent immune dendritiform cells (DCs). In this longitudinal study, eyes from 53 patients undergoing ICL surgery were assessed preoperatively and postoperatively over a twelve-month period. Quantification of seven SNP parameters was performed using ACCMetrics V.2 software. Ultimately, the final analysis was restricted to one eye from each of the 37 patients who completed a minimum of three months' postoperative follow-up. Preoperative investigations revealed a positive correlation of DC density with patient age and a negative association with corneal nerve fiber density (CNFD). Additionally, both DCs and CNFD were positively linked to spherical equivalent refraction (SER) and inversely related to axial length (AL). Intriguingly, preoperative DC density demonstrated an indirect relationship with both baseline and postoperative CNFD changes. Post-surgery, an initial surge in DC density was observed, which normalized subsequently. Meanwhile, parameters like CNFD, corneal nerve fiber length (CNFL), and corneal nerve fractal dimension (CNFrD) initially showed a decline following surgery. However, at one-year follow-up, CNFL and CNFrD displayed significant recovery, while CNFD did not return to its baseline level. This study thus delineates the regeneration pattern of SNP and alterations in DC density post-ICL surgery, highlighting that CNFD in the central cornea does not completely revert to preoperative levels within a year. Given these findings, practitioners are advised to exercise caution in older patients, those with high myopia, or elevated preoperative DCs who may undergo delayed SNP regeneration.

10.
BMC Ophthalmol ; 24(1): 143, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549060

RESUMO

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children. METHODS: This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ. RESULTS: The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05). CONCLUSION: The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.


Assuntos
Presbiopia , Refração Ocular , Criança , Humanos , Feminino , Masculino , Pré-Escolar , Adolescente , Testes Visuais , Córnea , Biometria , Comprimento Axial do Olho
11.
JNCI Cancer Spectr ; 8(2)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38556480

RESUMO

PURPOSE: Cancer survivors commonly report cognitive declines after cancer therapy. Due to the complex etiology of cancer-related cognitive decline (CRCD), predicting who will be at risk of CRCD remains a clinical challenge. We developed a model to predict breast cancer survivors who would experience CRCD after systematic treatment. METHODS: We used the Thinking and Living with Cancer study, a large ongoing multisite prospective study of older breast cancer survivors with complete assessments pre-systemic therapy, 12 months and 24 months after initiation of systemic therapy. Cognition was measured using neuropsychological testing of attention, processing speed, and executive function (APE). CRCD was defined as a 0.25 SD (of observed changes from baseline to 12 months in matched controls) decline or greater in APE score from baseline to 12 months (transient) or persistent as a decline 0.25 SD or greater sustained to 24 months. We used machine learning approaches to predict CRCD using baseline demographics, tumor characteristics and treatment, genotypes, comorbidity, and self-reported physical, psychosocial, and cognitive function. RESULTS: Thirty-two percent of survivors had transient cognitive decline, and 41% of these women experienced persistent decline. Prediction of CRCD was good: yielding an area under the curve of 0.75 and 0.79 for transient and persistent decline, respectively. Variables most informative in predicting CRCD included apolipoprotein E4 positivity, tumor HER2 positivity, obesity, cardiovascular comorbidities, more prescription medications, and higher baseline APE score. CONCLUSIONS: Our proof-of-concept tool demonstrates our prediction models are potentially useful to predict risk of CRCD. Future research is needed to validate this approach for predicting CRCD in routine practice settings.


Assuntos
Neoplasias da Mama , Sobreviventes de Câncer , Disfunção Cognitiva , Hominidae , Humanos , Feminino , Animais , Idoso , Sobreviventes de Câncer/psicologia , Neoplasias da Mama/complicações , Neoplasias da Mama/psicologia , Estudos Prospectivos , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/etiologia
12.
Invest Ophthalmol Vis Sci ; 65(3): 14, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38466287

RESUMO

Purpose: To investigate topographical maps of the three-dimensional choroidal vascularity index (3D-CVI) in children with different levels of myopia. Methods: We enrolled 274 eyes from 143 children with various severity of myopia, including emmetropia (EM), low myopia (LM), and moderate-high myopia (MHM). The choroidal vessel volume (CVV), choroidal stroma volume (CSV), and 3D-CVI in different eccentricities (fovea, parafovea, and perifovea) and quadrants (nasal, temporal, superior, and inferior) were obtained from swept-source optical coherence tomography angiography (SS-OCTA) volume scans. All choroidal parameters were compared among groups, and the associated factors contributing to different 3D-CVIs were analyzed. Results: Compared to the less myopic group, the more myopic group showed a significant decrease in CVV and CSV (MHM < LM < EM) and a significant increase in the 3D-CVI (MHM > LM > EM) in most areas (all P < 0.05). The nasal quadrant had the greatest 3D-CVI and lowest CSV and CVV, and vice versa in the temporal quadrant. The 3D-CVIs of the EM and LM groups gradually increased from the fovea to the perifovea, whereas the 3D-CVI of the MHM group first decreased and then increased. Regression analysis showed that axial length was an independent risk factor affecting foveal and parafoveal 3D-CVIs. Restricted cubic spline analysis revealed that the 3D-CVI increased with spherical equivalent (SE) when the SE was less than threshold and decreased when the SE was greater than threshold (SE thresholds for foveal, parafoveal, and perifoveal 3D-CVIs were -5.25 D, -5.125 D, and -2.00 D, respectively; all P < 0.05). Conclusions: Children with myopia exhibited decreased CSV and CVV, increased 3D-CVIs, and altered 3D-CVI eccentricity characteristics (from the fovea to the perifovea). The quadratic relationship between the 3D-CVI and SE should be explored in longitudinal investigations.


Assuntos
Encefalopatias , Miopia , Criança , Humanos , Miopia/diagnóstico , Corioide , Fóvea Central , Refração Ocular
13.
BMC Ophthalmol ; 24(1): 110, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454381

RESUMO

BACKGROUND: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). METHODS: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ([Formula: see text]orientation), and was compared pre- and post-operative. RESULTS: Following SMILE, the magnitude of chord u[Formula: see text]) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). CONCLUSIONS: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.


Assuntos
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Acuidade Visual , Pupila , Topografia da Córnea
14.
Front Public Health ; 12: 1352759, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38454995

RESUMO

Background: Myopia poses a global health concern and is influenced by both genetic and environmental factors. The incidence of myopia tends to increase during infectious outbreaks, such as the COVID-19 pandemic. This study examined the screen-time behaviors among Chinese children and adolescents and investigated the efficacy of artificial intelligence (AI)-based alerts in modifying screen-time practices. Methods: A cross-sectional analysis was performed using data from 6,716 children and adolescents with AI-enhanced tablets that monitored and recorded their behavior and environmental light during screen time. Results: The median daily screen time of all participants was 58.82 min. Among all age groups, elementary-school students had the longest median daily screen time, which was 87.25 min and exceeded 4 h per week. Children younger than 2 years engaged with tablets for a median of 41.84 min per day. Learning accounted for 54.88% of participants' screen time, and 51.03% (3,390/6,643) of the participants used tablets for 1 h at an average distance <50 cm. The distance and posture alarms were triggered 807,355 and 509,199 times, respectively. In the study, 70.65% of the participants used the tablet under an illuminance of <300 lux during the day and 61.11% under an illuminance of <100 lux at night. The ambient light of 85.19% of the participants exceeded 4,000 K color temperature during night. Most incorrect viewing habits (65.49% in viewing distance; 86.48% in viewing posture) were rectified swiftly following AI notifications (all p < 0.05). Conclusion: Young children are increasingly using digital screens, with school-age children and adolescents showing longer screen time than preschoolers. The study highlighted inadequate lighting conditions during screen use. AI alerts proved effective in prompting users to correct their screen-related behavior promptly.


Assuntos
Inteligência Artificial , Miopia , Criança , Humanos , Adolescente , Pré-Escolar , Lactente , Estudos Transversais , Pandemias , China
15.
Food Chem Toxicol ; 186: 114582, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38460668

RESUMO

Mycotoxins and thermal processing hazards are common contaminants in various foods and cause severe problems in terms of food safety and health. Combined use of acrylamide (AA) and ochratoxin A (OTA) would result in more significant intestinal toxicity than either toxin alone, but the underlying mechanisms behind this poor outcome remain unclear. Herein, we established the co-culture system of Caco-2/HT29-MTX cells for simulating a real intestinal environment that is more sensitive to AA and OTA, and showed that the combination of AA and OTA could up-regulate permeability of the intestine via increasing LY permeabilization, and decreasing TEER, then induce oxidative stress imbalance (GSH, SOD, MDA, and ROS) and inflammatory system disorder (TNF-α, IL-1ß, IL-10, and IL-6), thereby leading a rapid decline in cell viability. Western blot, PAS- and AB-staining revealed that AA and OTA showed a synergistic effect on the intestine mainly through the disruption of tight junctions (TJs) and a mucus layer. Furthermore, based on correlation analysis, oxidative stress was more relevant to the mucus layer and TJs. Therefore, our findings provide a better evaluation model and a potential mechanism for further determining or preventing the combined toxicity caused by AA and OTA.


Assuntos
Acrilamidas , Mucosa Intestinal , Ocratoxinas , Humanos , Células CACO-2 , Técnicas de Cocultura , Permeabilidade
16.
Antibiotics (Basel) ; 13(3)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38534634

RESUMO

AIMS: The aims of this study are to investigate the etiology, microbiological spectrum, and risk factors associated with visual outcomes of fungal endophthalmitis (FE) in a tertiary eye specialty hospital in Shanghai, China. METHODS: This was a retrospective, single-center case series. The clinical characteristics, etiology, microbiological spectrum, and management, as well as the visual outcomes, were analyzed. Logistic regression was used to analyze the factors related to visual outcomes. RESULTS: This study involved 102 eyes of 92 patients with FE, including 63 males (66.3%). The mean age was 44.4 ± 19.8 years. The most common etiology of FE was trauma (56.5%). The predominant fungal species isolated were Aspergillus spp. (31/93, 33.3%). Pars plana vitrectomy (PPV) and intravitreal antifungal agents was performed initially in 86 (84.3%) and 83 (81.4%) eyes, respectively. Only 35 (34.3%) eyes achieved final best corrected visual acuity (BCVA) of 20/400 or better. Ten (9.8%) eyes had a final BCVA of light perception or worse, and five (4.9%) had to be enucleated. The factors determining better visual outcomes included initial visual acuity better than finger-counting (FC) (odds ratio (OR) 5.811, p = 0.036), the absence of corneal infiltrate (OR 10.131, p = 0.002), and Candida species infection (OR 6.325, p = 0.011). CONCLUSIONS: Early diagnosis of FE and a timely vitrectomy, combined with an intravitreal injection of an antifungal drug, can mitigate the devastating results of intraocular fungal infection. Not being infected by Aspergillus spp., an initial BCVA that was no worse than FC, and the absence of corneal involvement were related to better visual prognosis.

17.
J Transl Med ; 22(1): 289, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494492

RESUMO

BACKGROUND: Global myopia prevalence poses a substantial public health burden with vision-threatening complications, necessitating effective prevention and control strategies. Precise prediction of spherical equivalent (SE), myopia, and high myopia onset is vital for proactive clinical interventions. METHODS: We reviewed electronic medical records of pediatric and adolescent patients who underwent cycloplegic refraction measurements at the Eye & Ear, Nose, and Throat Hospital of Fudan University between January 2005 and December 2019. Patients aged 3-18 years who met the inclusion criteria were enrolled in this study. To predict the SE and onset of myopia and high myopia in a specific year, two distinct models, random forest (RF) and the gradient boosted tree algorithm (XGBoost), were trained and validated based on variables such as age at baseline, and SE at various intervals. Outputs included SE, the onset of myopia, and high myopia up to 15 years post-initial examination. Age-stratified analyses and feature importance assessments were conducted to augment the clinical significance of the models. RESULTS: The study enrolled 88,250 individuals with 408,255 refraction records. The XGBoost-based SE prediction model consistently demonstrated robust and better performance than RF over 15 years, maintaining an R2 exceeding 0.729, and a Mean Absolute Error ranging from 0.078 to 1.802 in the test set. Myopia onset prediction exhibited strong area under the curve (AUC) values between 0.845 and 0.953 over 15 years, and high myopia onset prediction showed robust AUC values (0.807-0.997 over 13 years, with the 14th year at 0.765), emphasizing the models' effectiveness across age groups and temporal dimensions on the test set. Additionally, our classification models exhibited excellent calibration, as evidenced by consistently low brier score values, all falling below 0.25. Moreover, our findings underscore the importance of commencing regular examinations at an early age to predict high myopia. CONCLUSIONS: The XGBoost predictive models exhibited high accuracy in predicting SE, onset of myopia, and high myopia among children and adolescents aged 3-18 years. Our findings emphasize the importance of early and regular examinations at a young age for predicting high myopia, thereby providing valuable insights for clinical practice.


Assuntos
Miopia , Refração Ocular , Adolescente , Criança , Humanos , Miopia/diagnóstico , Miopia/epidemiologia , Pré-Escolar
18.
Eye Vis (Lond) ; 11(1): 9, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38433240

RESUMO

BACKGROUND: To evaluate the intraobserver repeatability and interobserver reproducibility of a newly developed dynamic real-time visualization 25 kHz swept-source optical coherence tomography (SS-OCT) based biometer (ZW-30, TowardPi Medical Technology Ltd, China) and compare its agreement with another SS-OCT based biometer (IOLMaster 700, Carl Zeiss Meditec AG, Jena, Germany). METHODS: Eighty-two healthy right eyes were enrolled in this prospective observational study. Measurements were repeated for three times using the ZW-30 and IOLMaster 700 in a random order. Obtained parameters included axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), astigmatism magnitude (AST), vector J0, vector J45, and corneal diameter (CD). The within-subject standard deviation (Sw), test-retest (TRT) variability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were adopted to assess the intraobserver repeatability and interobserver reproducibility. The double-angle plot was also used to display the distribution of AST. To estimate agreement, Bland-Altman plots were used. RESULTS: For the intraobserver repeatability and interobserver reproducibility, the Sw, TRT and CoV for all parameters were low. Meanwhile, the ICC values were all close to 1.000, except for the J45 (ICC = 0.887 for the intraobserver repeatability). The double-angle plot showed that the distribution of AST measured by these two devices was similar. For agreement, the Bland-Altman plots showed narrow 95% limits of agreements (LoAs) for AL, CCT, AQD, ACD, LT, Km AST, J0, J45, and CD (- 0.02 mm to 0.02 mm, - 7.49 µm to 8.08 µm, - 0.07 mm to 0.04 mm, - 0.07 mm to 0.04 mm, - 0.07 mm to 0.08 mm, - 0.16 D to 0.30 D, - 0.30 D to 0.29 D, - 0.16 D to 0.16 D, - 0.23 D to 0.13 D, and - 0.39 mm to 0.10 mm, respectively). CONCLUSIONS: The newly dynamic real-time visualization biometer exhibited excellent intraobserver repeatability and interobserver reproducibility. The two devices both based on the SS-OCT principle had similar ocular parameters measurement values and can be interchanged in clinical practice.

19.
Heliyon ; 10(5): e27052, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38439828

RESUMO

Background: Brittle cornea syndrome 1 (BCS1) is a rare autosomal recessive disorder characterized by corneal and sclera thinning and fragility that is caused by zinc finger protein 469 (ZNF469) gene mutation. Keratoconus is another disease related to corneal thinning. Several reports have linked ZNF469 variants and keratoconus. We recruited a four-generation BCS1 family and two keratoconus families to explore pathogenic ZNF469 variants. Methods: This study included 11 members from a family with BCS1, 2 families with keratoconus, 368 sporadic keratoconus patients and 325 unrelated healthy controls. Whole exome sequencing of DNA from peripheral blood and cross species conservation analysis was used to investigate and verify ZNF469 variants. Results: A new homozygous frameshift mutation c. 6727del (p.Asp2243Thr fs*8) in ZNF469 was detected in the BSC1 family. Two ZNF469 heterozygous variants g.88494671G > A (c.793G > A, p.G265S, rs754776767) were detected in keratoconus family 1 and a heterozygous missense variant g.88498262G > A (c.4384G > A, p.D1462 N, rs577890057) was found in keratoconus family 2. Based on the American College of Medical Genetics and Genomics guidelines, rs577890057 and rs754776767 were predicted to be variants of uncertain significance. c. 6727del (p. Asp2243Thr fs*8) in ZNF469 was identified to be pathogenic. Conclusions: We identified a new homozygous frameshift mutation and two heterozygous missense variations in ZNF469 in the three families. Our findings extend the spectrum of ZNF469 variants associated with keratoconus.

20.
Indian J Ophthalmol ; 72(Suppl 3): S429-S434, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38317330

RESUMO

PURPOSE: To investigate 7-year changes in corneal densitometry (CD) and its influencing factors following small incision lenticule extraction (SMILE) for moderate to high myopia. METHODS: A total of 32 patients (52 eyes) with a mean spherical equivalent (SE) refraction of -6.30 ± 1.30 D who underwent SMILE were recruited for this prospective study. Pre- and postoperative CD and corneal aberrations were measured by an oculus Pentacam system, and patients were followed up to 7 years. The CD evolution over time and its influencing factors were explored. RESULTS: No complications were observed after SMILE. There was a significant time effect on postoperative CD ( P < 0.05). The CD values at the 0-to-2 and 2-to-6 mm of the anterior layer increased at the first day ( P < 0.05) and declined to baselines at 1 year postoperatively; after that, CD values at any zone and any corneal layer presented a decreasing trend over time (all P < 0.05). Multivariate analysis showed that postoperative CD was positively correlated with age and optical zone (OZ), whereas negatively correlated with SE, corrected distance visual acuity (CDVA), and corneal aberrations (higher-order aberrations, Coma0 and Coma90) (all P < 0.05). Generalized estimating equation revealed that age, SE, CDVA, OZ, and Coma0 were the main factors influencing postoperative CD values (all P < 0.05). CONCLUSION: CD manifested a long-term decreasing trend in moderate to high myopia treated with SMILE. Its main influencing factors are age, SE, CDVA, OZ, and Coma0.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA